Aquatos Radar
Measures the distance to the water surface from a bridge or an outrigger. For streams, rivers, canals, retention basins and tanks.
Above the water or right in it: the right measurement for your site. Each sensor has its own page with a 3D view and data.
What matters is the installation location, maximum water column and medium.
| Aquatos Radar 0470 | Piezo pressure sensor 0312 | Ceramic pressure sensor 0420 | |
|---|---|---|---|
| Measurement | non-contact from above | directly in the water column | directly in the water column |
| Measuring range | 0.10 to 10 m distance | 5 to 100 m H₂O | 0 to 1 bar, about 10 m H₂O |
| Principle | 60 GHz radar | piezoresistive | capacitive, ceramic diaphragm |
| Fits when | a bridge or outrigger is available and nothing should go into the water | well, gauge tube or deep level, high accuracy needed | basin, wastewater plant or polluted water, shallow level |
| Quiescent current | <30 µA | <10 µA | <10 µA |
| Interfaces | SDI-12 V1.3 and Bluetooth Low Energy | ||
The radar sensor stays above the water, the pressure probes measure directly in the water column.

Measures the distance to the water surface from a bridge or an outrigger. For streams, rivers, canals, retention basins and tanks.

For groundwater and water levels at different measuring depths. As gauge or absolute pressure probe, with a stainless steel or titanium diaphragm.

For basins and wastewater plants that need a resistant pressure diaphragm. We match the media compatibility to your measuring site.
Single or combined. The choice depends on the water body, measuring task and installation.

Track conductivity and temperature in groundwater and surface water. The CTD probe also records pressure and fits into 2-inch gauge tubes.

For tracking conductivity and temperature in groundwater and surface water.

Continuously monitor the oxygen content of the water, to assess waters and changes over time.

Glass-body electrode for wastewater and drinking-water monitoring.

Measures the nitrate content with UV light directly in the water, without reagents or sampling.

One measuring point, more insight: record several variables together, for example pH, oxygen, conductivity and turbidity.
For stratification analysis and the annual cycle across all depths.

Up to 30 nodes on one chain, positioned to your specification. For stratification analysis and the annual cycle across all depths.
Sensors for precipitation and climate, connected via SDI-12 or Modbus.

Heated tipping bucket with funnel and tipping mechanism for year-round measurement.

Weighing precipitation gauge in stainless steel for year-round recording to WMO-No.8, including snow and hail.

Detects precipitation acoustically and optically and provides intensity and type (rain, snow, hail), plus air temperature and humidity.
Rain gauges, water meters and Modbus sensors become part of the SDI-12 bus.

For tipping-bucket rain gauges and water meters with pulse output.

Connects sensors with a Modbus RS485 interface to the SDI-12 bus.
The sensors work with the Aquatos data loggers from TerraTransfer GmbH. You will find all details on terratransfer.de.